Architecture Fabric (SF)
Architectural PTFE membrane is manufactured by coating glass fiber with PTFE resin
Characteristics
Features
Light yet strong mechanical properties |
Excellent fire resistance |
High mining rate |
Implementation of various designs |
High self-cleaning ability |
Short construction period |
High durability (more than 25 years) |
Excellent sound absorption characteristics |
Usage
Sports facilities such as playgrounds and gyms |
Bus and train stops |
Traditional market |
Other resting facilities and landscaping facilities |
Performance hall |
Structure
Architecture Fabric (SF) / Product type and physical properties table
Architecture Fabric (SF)
Architectural PTFE membrane is manufactured by coating glass fiber with PTFE resin
Characteristics
Features
Light yet strong mechanical properties |
Excellent fire resistance |
High mining rate |
Implementation of various designs |
High self-cleaning ability |
Short construction period |
High durability (more than 25 years) |
Excellent sound absorption characteristics |
Usage
Sports facilities such as playgrounds and gyms |
Bus and train stops |
Traditional market |
Other resting facilities and landscaping facilities |
Performance hall |
Structure
Architecture Fabric (SF) / Product type and physical properties table
Series No | SF-850 | SF-950 | SF-1110 | SF-1120 | SF-1300 | SF-1420 | ||
Coating Material | PTFE | PTFE | PTFE | PTFE | PTFE | PTFE | ||
Glass Cloth | Woven “EC6” glass EC6 68TEX x 3 Warp 11 Weft 9 | Woven “EC6” glass EC6 68TEX x 3 Warp 11 Weft 9 | Woven “EC6” glass EC6 68TEX x 3 Warp 11 Weft 9 | Woven “EC3” glass ECB 150 2 x 3 Warp 10 Weft 8.5 | Woven “EC3” glass ECB 150 4 x 2 Warp 10 Weft 8 | Woven “EC6” glass EC6 68TEX x 2 x 3 Warp 8 Weft 7.3 | ||
Applications | Small Air & Tensile structures | Small Air & Tensile structures, clear spans, tesion tents | Small Air & Tensile structures, clear spans, tesion tents | Small Air & Tensile structures, clear spans, tesion tents | Small Air & Tensile structures, clear spans, tesion tents | Small Air & Tensile structures, clear spans, tesion tents | ||
Unit | Values | Test Method | ||||||
Coating Fabric Weight (nom.±5%) | g/㎡ | 850 | 950 | 1100 | 1100 | 1335 | 1400 | DIN EN 22286 |
Thickness (nominal) | micron | 510 | 540 | 600 | 620 | 800 | 950 | DIN EN 22286 |
Tensile Strength | B53424 Part 4 | |||||||
Wrap (Nominal) | N/5cm | 6000 | 6000 | 6500 | 7300 | 7800 | 7800 | Method 6 or DIN 53354 |
Fill (Nominal) | N/5cm | 5000 | 5300 | 5300 | 6000 | 6600 | 6900 | |
Strip Tensile-Wet | ||||||||
Warp(min.) | N/5cm | n.a. | n.a. | n.a. | n.a. | n.a. | n.a. | |
Fill(min.) | N/5cm | n.a. | n.a. | n.a. | n.a. | n.a. | n.a. | |
Tear Strength Wrap (Nominal/min.) | N | 360/275 | 360/275 | 360/275 | 360/330 | 430/350 | 580/500 | B57304 Part4 |
Fill (Nominal/min.) | N | 360/275 | 400/275 | 400/275 | 400/330 | 460/350 | 680/500 | |
Coating Adhesion (Nominal/min.) | N/5cm | 75/50 | 75/50 | 75/50 | 120/70 | 130/80 | 100/75 | B53424 Part 7 |
Elongation at break (uniaxial) | ||||||||
Wrap | % | 3~10 | 3~10 | 3~10 | 3~10 | 3~10 | 2~15 | |
Fill | % | 5~17 | 5~17 | 5~17 | 5~17 | 5~16 | 3~17 | |
Elongation at break (uniaxial) | ||||||||
Wrap | % | 3~10 | 3~10 | 3~10 | 3~10 | 3~10 | 2~15 | |
Fill | % | 5~17 | 5~17 | 5~17 | 5~17 | 5~16 | 3~17 | |
Solar Transmission (550nm) | % | n.a. | n.a. | n.a. | n.a. | n.a. | n.a. | VIT Test |
Solar Transmission (nominal) | % | 15~25 | 15~25 | 15~25 | 15~25 | 7.5~17.5 | 3~23 | ASTM E-424-71 |
Solar Reflectance (nominal) | % | 70~80 | 70~80 | 70~80 | 70~80 | 70~90 | 67~87 | ASTM E-424-71 |
Width | m | 2.95, 3.85 | 2.95, 3.85 | 2.95, 3.85 | 2.95 | 2.85, 3.75 | 3.6 | |
Color | - | White(after exposure to sunlight | White(after exposure to sunlight | White(after exposure to sunlight | White(after exposure to sunlight | White(after exposure to sunlight | White(after exposure to sunlight |
The information provided above is based on our general experience and is given in good faith.
However, we cannot assume responsibility for factors that are beyond our knowledge or control.
The information provided above is based on our general experience and is given in good faith.
However, we cannot assume responsibility for factors that are beyond our knowledge or control.
Architecture Fabric (SF) Color chart
Architecture Fabric (SF) / Usage and construction examples
Figure 01. Gocheok Sky Dome (Constructor: Tiger)
Figure 02. Pyeongchang Ice Arena (Constructor: Dongast)
Figure 03. Hadong coal storage site (Constructor: Tiger)
Figure 04. Side of Pyeongchang Ice Arena (Constructor: Dongast)
Figure 05. Yeongdong-gun Sports Complex (Constructor: Dongast)
Figure 06. Okcheon-gun Tennis Court (Constructor: Dongast)
Figure 07-1. Indoor Gymnasium (Constructor: Dongast)
Figure 07-2. Indoor Gymnasium (Constructor: Dongast)
Architecture Fabric (SF) Color chart
Architecture Fabric (SF) / Usage and construction examples
Figure 01. Gocheok Sky Dome (Constructor: Tiger)
Figure 02. Pyeongchang Ice Arena (Constructor: Dongast)
Figure 03. Hadong coal storage site (Constructor: Tiger)
Figure 04. Side of Pyeongchang Ice Arena (Constructor: Dongast)
Figure 05. Yeongdong-gun Sports Complex (Constructor: Dongast)
Figure 06. Okcheon-gun Tennis Court (Constructor: Dongast)
Figure 07-1. Indoor Gymnasium (Constructor: Dongast)
Figure 07-2. Indoor Gymnasium (Constructor: Dongast)
AMMK CO.,LTD
Head Office: 10, Hwangsaeul-ro 351beon-gil, Bundang-gu Seongnam-si, Gyeonggi-do, Korea
Tel : +82-31-704-1858Fax : +82-31-704-1857
Ⓒ Copyright AMMK CO.,LTD. All rights reserved.
AMMK CO.,LTD
Head Office : 10, Hwangsaeul-ro 351beon-gil, Bundang-gu Seongnam-si, Gyeonggi-do, Korea
Tel : +82-31-704-1858Fax : +82-31-704-1857
Ⓒ Copyright AMMK CO.,LTD. All rights reserved.